Also, a prompt that can be in-
voked on the display in engi-
neer mode (e.g., cn.1); if
selected, it provides scrolling
capabilities through a series
of parameter prompts for con-
figuration purposes.
Parameter
One of many prompts subor-
dinated to a selected module
of the conF or ProG menus,
or a prompt in the oPEr menu,
that solicits configuration in-
put. Configuring a parameter
may require data to be en-
tered, a YES/no choice to be
made, or a selection made
from a list of items that ap-
pear sequentially in the red
dro as the scroll for-
ward/backward push buttons
are pressed.
Pass-Key
Two pass-keys can be config-
ured for the 53SL6000 con-
troller. A pass-key is a four
digit numeric value entered in
the red dro in response to the
key query to gain access to
either the conF menu or the
ProG menu in engineer
mode.
PID
A mnemonic that represents
the proportional, integral, and
derivative actions caused by
the control scheme algorithm
output.
Process
Variable
The process feedback input
signal provided by a measur-
ing transmitter device that is
computed against the control-
ler setpoint to determine the
deviation error and required
output to null the error.
Prompt
An engineer mode alphanu-
meric assigned to a menu,
module, or parameter that ap-
pears in a dro.
Proportional
Action (Pb)
Proportional action (Pb) pro-
duces a value calculated from
the difference between the
setpoint and process variable
values. Proportional action is
set as a percentage of the
proportional band (%PB) from
2% (narrow band - maximum
action) to 1000% (wide band -
minimum action).
Proportional
Speed
Floating
Control
This time proportional or
three step output is applica-
ble to all of the control
schemes. The controller out-
put is provided as hardware
contact levels from DO3 and
DO4 that are proportional to
the quantitative requirements
of the corrective action. It is
especially useful for motor-
ized control valves, whereby
the DO3 output drives the
valve in one direction and the
DO4 output drives the valve
in the opposite direction.
Push
Button
Any one of seven tactile
switches on the 53SL6000
controller faceplate used for
display panel operations.
Ratio
Control
A control strategy whereby
the controller maintains a
process variable in relation to
a measured wild variable.
This control strategy is imple-
mented in the 53SL6000 con-
troller with the factory default
settings, by selecting SnGL
for the ProG-cS-SchM pa-
rameter, and by selecting
K-SP for the setpoint mode
parameter conF-cn.1-SPM.
RS-232
Module
An option module that at-
taches to the rear of the
53SL6000 controller case to
provide personal computer
RS-232 COMM port connec-
tivity.
RS-485
Module
An option module that at-
taches to the rear of the
53SL6000 controller case to
provide datalink connectivity.
Setpoint
A displayed controller value
that represents a desired qui-
53SL6000 Instruction Manual Appendix A. Glossary